D4SL-N

Caracteristici

Comutator pentru uşi de securitate cu dispozitiv de blocare

Dispozitivele D4SL-N oferă o gamă variată de modele pentru monitorizarea în siguranţă a intrărilor şi poziţiei dispozitivelor de blocare.

  • Forţă de fixare a cheii 1300 N
  • Tipuri cu 4, 5 şi 6 contacte
  • Tipuri cu bloc terminal şi tipuri de conector
  • Solenoid de acţionare direct de la controler
  • Punct de inserţie al cheii rotative fără detaşarea capului
Specificaţii şi informaţii pentru comenzi

Ordering information

Contact configuration

 

Contact model

Built-in Switch

4-contact model

Door monitor and Lock monitor are connected in series internally.

A: 1NC/1NO + 1NC/1NO

B: 1NC/1NO + 2NC

C: 2NC + 1NC/1NO

D: 2NC + 2NC

 

Door monitor and Lock monitor are NOT connected in series internally.

S: 1NC/1NO + 1NC/1NO

T: 1NC/1NO + 2NC

U: 2NC + 1NC/1NO

V: 2NC + 2NC

 

Contact model

Built-in Switch

5-contact model

E: 2NC/1NO + 1NC/1NO

F: 2NC/1NO + 2NC

G: 3NC + 1NC/1NO

H: 3NC + 2NC

6-contact model

N: 2NC/1NO + 2NC/1NO

P: 2NC/1NO + 3NC

Q: 3NC + 2NC/1NO

R: 3NC + 3NC

Models

Housing

Release

key type

Wiring method

Solenoid voltage/Indicator

Lock and release type

Contact configuration

(door open/closed detection switch and lock monitor switch contacts)

Conduit size1

Order code

Head Resin/ Body Resin2

Standard (metal)3

 

Connector

24 VDC

(Orange)

Mechanical lock Solenoid release

6-contact Model

Insert the built-in switch (N, P, Q or R) into the blank _.

M20

D4SL-N4_FA-DN

5-contact Model

Insert the built-in switch (E, F, G or H) into the blank _.

M20

D4SL-N4_FA-DN

24 VDC

(without indicator)

4-contact Model

Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank _.

M20

D4SL-N4_FA-N

Terminal block

24 VDC

(Orange)

6-contact Model

Insert the built-in switch (N, P, Q or R) into the blank _.

M20

D4SL-N4_FA-D

5-contact Model

Insert the built-in switch (E, F, G or H) into the blank _.

M20

D4SL-N4_FA-D

24 VDC

(without indicator)

4-contact Model

Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank _.

M20

D4SL-N4_FA

Connector

24 VDC

(Orange)

Solenoid lock Mechanical release

6-contact Model

Insert the built-in switch (N, P, Q or R) into the blank _.

M20

D4SL-N4_FG-DN

5-contact Model

Insert the built-in switch (E, F, G or H) into the blank _.

M20

D4SL-N4_FG-DN

24 VDC

(without indicator)

4-contact Model

Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank _.

M20

D4SL-N4_FG-N

Terminal block

24 VDC

(Orange)

6-contact Model

Insert the built-in switch (N, P, Q or R) into the blank _.

M20

D4SL-N4_FG-D

5-contact Model

Insert the built-in switch (E, F, G or H) into the blank _.

M20

D4SL-N4_FG-D

24 VDC

(without indicator)

4-contact Model

Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank _.

M20

D4SL-N4_FG

Operation keys (order separately)

Type

Order code

 

Type

Order code

Horizontal mounting

 

D4SL-NK1

 

Vertical mounting

 

D4SL-NK2

Horizontal mounting

(Short)

 

D4SL-NK1S

 

Vertical mounting

(Cushion rubber)

 

D4SL-NK2G

Horizontal mounting

(Cushion rubber)

 

D4SL-NK1G

 

Adjustable

(Horizontal)

 

D4SL-NK3

 

 

 

 

Adjustable

(Horizontal/Vertical)

 

D4SL-NK5

Connector cables for connector types

Cable length

Order code

1 m

D4SL-CN1

3 m

D4SL-CN3

5 m

D4SL-CN5

10 m

D4SL-CN10

Specifications

Degree of protection4

IP67 (EN60947-5-1)

Durability5

Mechanical

1,000,000 operations min.

Electrical

150,000 operations min. (1 A resistance at 125 VAC)6

Operating speed

0.05 to 1 m/s

Operating frequency

5 operations minute max.

Direct opening force7

60 N min. (EN60947-5-1)

Direct opening travel4

15 mm min. (EN60947-5-1)

Holding force

1,300 N min.

Minimum applicable load

1 mA resistive load at 5 VDC (N-level reference value)

Rated insulation voltage (Ui)

150 V (EN60947-5-1)

Rated frequency

50/60 Hz

Protection against electric shock

Class II (double insulation)

Pollution degree (operating environment)

3 (EN60947-5-1)

Conditional short-circuit current

100 A (EN60947-5-1)

Conventional free air thermal current (Ith)

2.5 A (11-42, 21-52, 21-22)

1 A (Others)

Ambient operating temperature

10 to 55 ° C (with no icing)

Ambient operations humidity

95% max.

 

  • Note 1. The above values are initial values.
  • 2. The switch contacts can be used with either standard loads or microloads.

1. Types also with G1/2 and 1/2-14NPT available - see online data sheet

2. 'Head metal/Body resin' also available - see online data sheet

3. Release key type also resin available - see online data sheet

4. This applies for the switch only. The degree of protection for the key hole is IP00.

5. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative.

6. Do not pass the 1 A, 125 VAC load through more than 3 circuits.

7. These figures are minimum requirements for safe operation.

1. Types also with G1/2 and 1/2-14NPT available - see online data sheet

2. 'Head metal/Body resin' also available - see online data sheet

3. Release key type also resin available - see online data sheet

4. This applies for the switch only. The degree of protection for the key hole is IP00.

5. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative.

6. Do not pass the 1 A, 125 VAC load through more than 3 circuits.

7. These figures are minimum requirements for safe operation.

Aveţi întrebări?

Suntem pregătiţi de ajutor.

Contactaţi-ne

Abonaţi-vă la actualizările de produs

Buletine informative despre inovaţii de produs, soluţii şi servicii, direct în inboxul dvs.

Vă mulțumim pentru abonarea la buletinul de știri Omron. Veți primi în curând un e-mail de la noi. Acest e-mail conține un link prin care activați abonarea la buletinul de știri pe e-mail. Această metodă este folosită din motive juridice și pentru a fi siguri că nimeni nu va folosi abuziv adresa dumneavoastră de e-mail.

Întâmpinăm dificultăţi tehnice. . Formularul dumneavoastră nu a fost preluat cu succes. Vă rugăm să acceptaţi scuzele noastre şi să încercaţi încă odată mai târziu. Detalii: [details]

Download

Documentaţie de produs

Descărcaţi fişe de date, manuale şi broşuri.

Căutaţi în centrul de descărcare

Cursuri de instruire

Beneficiaţi de instruire de la cei mai buni dintre inginerii noştri. De la începător la avansat.

Vizualizaţi cursuri de instruire