XW2F
Unități de conversie conector-bloc terminal pentru dispozitive de uz general
Numeroase variaţii privind conectorii şi numărul de poli.
- Modele disponibile cu şurub cu cap Phillips, şurub cu cap crestat, conexiuni Push-in sau e-CON.
- Dispunerea terminalelor permite cablarea mai uşoară.
- Terminalele Push-in simplifică cablarea şi facilitează utilizarea blocurilor terminale. (În comparaţie cu OMRON XW2F.)
- Este posibilă montarea pe şină DIN.
Specificaţii şi informaţii pentru comenzi
Ordering Information
With power supply terminals
e-CON Type
Appearance | I/O Points | I/O | Mounted Connector model | Cable Connector model | Order code
2
Only DIN Track mounting models
are described here. Refer to the XW2R-series Connector-Terminal
Block Conversion Units Catalog (Cat. No. G077) for information on
screw mounting models. |
---|---|---|---|---|---|
![]() |
8 Points | Input | XG4A-1431 (MIL Connector) XN2D-4471 (e-CON Connector) |
XG4M-1430-T (MIL Connector) XN2A-1470 (e-CON Connector) |
XW2R-N08GD-COM |
Input Device Connectors
XN2 e-CON Connectors
Appearance | Number of poles | Description | Order code |
---|---|---|---|
![]() |
4 | For Sensor | XN2A-1470 |
![]() |
4 | Relay Connector | XN2B-1470 |
Without power supply terminals
Phillips screw
Appearance
2
The mounted Connector shown in
the appearance illustration is a MIL Connector. |
Mounted Connector model | Number of poles | Dimension A (mm) | Order code
2
Only DIN Track mounting models
are described here. Refer to the XW2R-series Connector-Terminal
Block Conversion Units Catalog (Cat. No. G077) for information on
screw mounting models. |
|
---|---|---|---|---|---|
![]() |
MIL Connector | XG4A-2031 | 20 | 81.7 | XW2R-J20GD-T |
XG4A-3431 | 34 | 130.7 | XW2R-J34GD-T | ||
XG4A-4031 | 40 | 151.7 | XW2R-J40GD-T | ||
XG4A-5031 | 50 | 186.7 | XW2R-J50GD-T | ||
XG4A-6031 | 60 | 221.7 | XW2R-J60GD-T | ||
FCN Connector | FCN-364P040-AU | 40 | 151.7 | XW2R-J40FD-T |
Slotted screw (rise up)
Appearance
2
The mounted Connector shown in
the appearance illustration is a MIL Connector. |
Mounted Connector model | Number of poles | Dimension A (mm) | Order code
2
Only DIN Track mounting models
are described here. Refer to the XW2R-series Connector-Terminal
Block Conversion Units Catalog (Cat. No. G077) for information on
screw mounting models. |
|
---|---|---|---|---|---|
![]() |
MIL Connector | XG4A-2031 | 20 | 64.4 | XW2R-E20GD-T |
XG4A-3431 | 34 | 98.5 | XW2R-E34GD-T | ||
XG4A-4031 | 40 | 113.5 | XW2R-E40GD-T | ||
XG4A-5031 | 50 | 138.5 | XW2R-E50GD-T | ||
XG4A-6031 | 60 | 163.5 | XW2R-E60GD-T | ||
FCN Connector | FCN-364P040-AU | 40 | 113.5 | XW2R-E40FD-T |
Push-in spring
Appearance
2
The mounted Connector shown in
the appearance illustration is a MIL Connector. |
Mounted Connector model | Number of poles | Dimension A (mm) | Order code
2
Only DIN Track mounting models
are described here. Refer to the XW2R-series Connector-Terminal
Block Conversion Units Catalog (Cat. No. G077) for information on
screw mounting models. |
|
---|---|---|---|---|---|
![]() |
MIL Connector | XG4A-2031 | 20 | 64.4 | XW2R-P20GD-T |
XG4A-3431 | 34 | 98.5 | XW2R-P34GD-T | ||
XG4A-4031 | 40 | 113.5 | XW2R-P40GD-T | ||
XG4A-5031 | 50 | 138.5 | XW2R-P50GD-T | ||
XG4A-6031 | 60 | 163.5 | XW2R-P60GD-T | ||
FCN Connector | FCN-364P040-AU | 40 | 113.5 | XW2R-P40FD-T |
Specifications
Item | XW2R-N |
XN2 |
XW2R-J |
XW2R-E |
XW2R-P |
|
---|---|---|---|---|---|---|
Rated current | Power supply terminal block: 2 A, Connectors/e-CON Connectors: 1 A (However, rated current of e-CON Connector depends on the wires that are used.) |
3 A/pin (with AWG20 wires), 2 A/pin (with AWG22 wires), 1 A/pin (with AWG24 wires), 0.5 A/pin (with AWG26 or AWG28 wires) | 1 A | |||
Rated voltage | 24 VDC | 32 VDC | 125 VAC, 24 VDC | |||
Contact resistance | – | 30 mΩ max. (at 20 mV, 100 mA max.) |
– | |||
Insuration resistance | 100 MΩ min. (at 500VDC) | 103 MΩ min. (at 500 VDC) | 100 MΩ min. (at 500 VDC) | |||
Dielectric strength | 500 VAC for 1 min (leakage current: 1 mA max.) |
1,000 VAC for 60 sec (leakage current: 1 mA max.) |
500 VAC for 1 min (leakage current: 1 mA max.) |
|||
Insertion durability | – | 50 times | – | |||
Ambient operating temperature | 0 to 55°C | –30 to 75°C
2
The operating temperature range
is restricted by the maximum operating temperature of the cable. |
0 to 55°C | |||
Applicable wires |
Applicable wire sizes
2
This is the applicable range for the Power supply terminals. |
AWG 24 to 14 (ferrules), AWG 28 to 14 (stranded wires), AWG 28 to 16 (solid wires) (Outer diameter of insulation must be 4 mm max) |
Stranded wire 0.08 mm 2 (AWG28) to 0.5 mm 2 (AWG20) (Outer diameter of insulation must be 1.5 mm max) |
AWG 22 to 16 (round or forked crimp terminals) AWG 26 to 16 (stranded or solid wires) |
AWG 22 to 16 (ferrules) AWG 26 to 16 (stranded or solid wires) |
AWG 24 to 14 (ferrules) AWG 28 to 14 (stranded or solid) (Outer diameter of insulation must be 4 mm max) |
Stripped length |
AWG28-16: 8 to 10 mm AWG14: 9 to 10 mm |
– | 9 mm | 7 mm | AWG28-16: 8 to 10 mm AWG14: 9 to 10 mm |
|
Tightening | – | 0.5 N·m | 0.5 to 0.6 N·m | – |
Cum vă putem ajuta?
Dacă aveţi întrebări sau doriţi să cereţi o ofertă, contactaţi-ne sau trimiteţi-ne o solicitare.
Contactați-mă XW2F

Vă mulțumim pentru solicitarea trimisă. Vom reveni cu un răspuns cât mai curând posibil.
Întâmpinăm dificultăţi tehnice. . Formularul dumneavoastră nu a fost preluat cu succes. Vă rugăm să acceptaţi scuzele noastre şi să încercaţi încă odată mai târziu. Detalii: [details]
DownloadOfertă pentru XW2F
Prin completarea acestui formular puteţi face o cerere de ofertă. Vã rugãm completaţi toate câmpurile marcate cu *. Datele dumneavoastrã personale vor fi tratate cu confidențialitate.

Vă mulțumim pentru cererea de ofertă trimisă. Vă vom oferi informațiile cerute în cel mai scurt timp posibil.
Întâmpinăm dificultăţi tehnice. . Formularul dumneavoastră nu a fost preluat cu succes. Vă rugăm să acceptaţi scuzele noastre şi să încercaţi încă odată mai târziu. Detalii: [details]
DownloadDocumentare